Applications: control panel builders
These product lines serve the control panel, from the incoming power to the last field wire. The lines cover protection and switching, 24 V control power, the logic and the network, and the terminals, marking and cable entry. The manufacturers Dynamic Measurement and Control Solutions represents, on a line card built for the way you design, with an application engineer on the phone before the spec locks.
A control panel takes in the power, protects each branch, makes the 24 V the controls run on, and lands every field wire. Before the parts are picked, settle the standard (usually UL 508A), the short-circuit rating the site needs, and the space and heat the enclosure allows.
A panel that will not close goes up an enclosure size. Space comes back from parts that do two jobs, shed less heat or sit at the wall.
Panel spaceEvery screw terminal is landed, then checked to torque. Push-in points and markers printed from the drawing take that step out of each build.
Build laborA molded connector will not pass through a standard gland, so it gets cut off and re-terminated. A split entry passes the cable whole.
Panel Wiring Field GuideThe lowest-rated part sets the panel's short-circuit rating. Pick parts with a marked rating and a listing the inspector can read.
Safety, approvals and standards
A short at the far end of a 24 V run may not trip a thermal-magnetic breaker fast. The EFC electronic fuse protects four 24 V channels of up to 5 A each and switches off only the channel at fault. A Premium supply with the battery charger and changeover built in holds the 24 V through a mains dip.

A DC bus never crosses zero, so the contactor has to stretch and cool the arc itself. Schaltbau DC contactors use permanent-magnet arc blowout in an open chamber. The C310 and C320 are UL Recognized Components to UL 60947-4-1. We confirm the rating for your voltage and current before it goes on the drawing.

A temperature loop can switch its output several times a minute for years. A solid state relay has no contact to erode. Celduc covers 4 to 125 A, single and three phase, with a 22.5 mm DIN-rail family and versions that arrive on their own heatsink.

Procon rectangular connectors carry power, signal and Ethernet out of the panel through one hood, 3 to 288 pins, with screw, crimp or push-in inserts. You wire and test at your bench. On the customer's floor the inserts mate, the hood snaps and the panel is connected.

IMO's UB10 range is UL 489 miniature circuit breakers from 0.5 to 63 A, the branch-circuit protection a panel inspector expects. Motor circuit breakers, RCBOs and surge protection come from the same catalog. Contactors with a 3 W sealed coil run cool in a full panel.

iSmart smart relays and XGB PLCs come with license-free programming, so the software is not a cost on every small panel job. Jaguar drives, and iView HMIs for the door, come from the same maker. Same-day dispatch from US stock, up to 5-year warranty on electromechanical components.

The SW-7617 puts sixteen 10/100 ports and an SFP slot on one DIN-rail footprint, so four more drops do not need a second switch. Remote I/O and Ethernet-to-serial units sit beside it and run from any DC supply up to 30 V already in the panel. One uplink leaves the enclosure.

BFM-II meters up to 54 single-phase or 18 three-phase circuits from one DIN-rail unit and reports current unbalance on each three-phase circuit. A motor control panel ships with the metering for every motor already in it.

One PPVK feed-in splits the 24 V or the 0 V across a row of push-in points, with no torque check on each one. The blocks are now UL approved. Orange, red, blue and white pushers tell the circuits apart.

TTPCardMAX prints markers in the shop, up to 5,500 an hour. Marker cards fit most common DIN-rail terminal block families, so the number on the block is the number on the drawing.

KDS split cable entry: the cable goes through the frame with its connector on, the wave-cut seal closes around it, and the frame holds IP66. UL Recognized, one frame in place of a row of glands, seals swapped from outside.

ESKV polyamide glands run M12 to M63 and NPT 1/4 to 2 inch. EMC versions land the cable shield at the enclosure wall. Junction boxes and the Brace conduit system come from the same maker.
Dynamic Measurement and Control Solutions supports panel shops and machine builders there as the manufacturers' representative for Premium PSU, Walther Electric, Schaltbau, Celduc, IMO Automation, GETT, SATEC, Brainboxes, Knick Interface and Conta-Clip. An application engineer helps you specify the parts. The parts are quoted through the distributor you already buy from.
The lowest-rated power part sets it. UL 508A, Supplement SB, gives a low default rating to a part with no marked rating, and that one part can hold the whole panel at the default. A current-limiting fuse or breaker upstream can raise the rating of the parts behind it, within the limits the standard sets.
A UL 489 listed breaker is the branch-circuit protective device a panel inspector expects on each branch. A supplementary protector is not a substitute for a UL 489 breaker. IMO's UB10 range is UL 489 from 0.5 to 63 A, and we confirm the exact part and its listing when you specify it.
Use a 24 V supply with a DC UPS built in. A Premium PSU unit takes in the AC mains, charges its battery and changes over when the mains drops. Alarm contacts report mains failure and battery low, so a dip is a logged event and not a controller restart.
The load list with voltages and currents, the standard the panel is built to, the available fault current at the site, and the build quantity. From that we help you pick the parts and confirm each listing and rating, with the manufacturer where a rating needs it.
Written for the engineers who design machines and control panels
Use these to check your own design: Panel Wiring Field Guide · UL 508A Control Panel Compliance Checklist (PDF) · UL Marks Quick Reference (PDF) · Build a Better Panel (PDF) · All design guidance
Design Path chapters for this application
Power That Performs covers the control power, the electronic fuse and the DC and solid state switching. Machine Intelligence & Control covers the breakers, the smart relay, the PLC and the drive. Industrial Data Pathways covers the network switch, the remote I/O and the meter. Wired to Last covers the terminal blocks, the marking, the cable entry and the connectors.
Control panels are one application under Industrial Automation and Production Equipment: the power connection, the controls and the data port on the machine you ship.
A question that comes up mid-design is exactly what we are for. Ask about the branch protection, the control power, the terminal blocks or the cable entry. A short technical conversation before the spec locks usually surfaces the options a datasheet does not.
Power it. Control it. Prove it.
The same twelve tiles as a two-page PDF, with the band each manufacturer sits in. The card covers protection and switching, control power, the logic and the network, and the terminals, marking and cable entry. Made for the drawing set, not the inbox.
All product lines, including GETT operator panels and Knick signal isolators: www.dynamicrep.com/products