Dynamic Measurement and Control Solutions
    • Applications
      • Industrial Automation & Production Equipment
      • Semiconductor & Test Equipment
      • Robotics, Robot Cells & Mobile Robots
      • Food, Beverage & Process Equipment
      • Life Sciences, Medical & Laboratory Equipment
      • Commercial, Self-Service & Public-Use Equipment
      • Transportation, Mobility & Vehicle Systems
      • Heavy Equipment, Mobile Machinery & Outdoor Systems
      • Energy, Power & Electrification Systems
      • Data Centers & Digital Infrastructure
      • Building, Facility & Site Systems
    • Products
    • Design Path
      • The Design Path
      • Design Once, Build Many
      • Power That Performs
      • Machine Intelligence & Control
      • Industrial Data Pathways
      • Wired to Last
    • Design Guidance
    • The Detail
    Dynamic Measurement and Control Solutions
    Opens mobile navigation.

    Click to call. 4087809190

    • Applications
      • Industrial Automation & Production Equipment
      • Semiconductor & Test Equipment
      • Robotics, Robot Cells & Mobile Robots
      • Food, Beverage & Process Equipment
      • Life Sciences, Medical & Laboratory Equipment
      • Commercial, Self-Service & Public-Use Equipment
      • Transportation, Mobility & Vehicle Systems
      • Heavy Equipment, Mobile Machinery & Outdoor Systems
      • Energy, Power & Electrification Systems
      • Data Centers & Digital Infrastructure
      • Building, Facility & Site Systems
    • Products
    • Design Path
      • The Design Path
      • Design Once, Build Many
      • Power That Performs
      • Machine Intelligence & Control
      • Industrial Data Pathways
      • Wired to Last
    • Design Guidance
    • The Detail

    Let's get in touch

    Fill out this form, and we'll contact you soon.

    What are you designing for? Footprint.

    Where do the inches go in a control panel, and how do you get them back?

    Panel space goes to parts doing one job each, to heat and to wiring room. Space comes back where one part does two jobs, sheds less heat or moves out of the main panel.

    Ask a questionWalk the design path

    Conta-Clip KDS split cable entry frame with pre-terminated cables passing through
    One split frame in place of a row of glands
    55 x 55 x 10 mmBrainboxes board-level Ethernet switching, designed into the enclosure instead of bolted on
    Up to 54 circuitsSATEC BFM-II branch feeder monitor from one DIN-rail unit
    22.5 mmCelduc celpac DIN-rail solid state relays
    One frameConta-Clip KDS split cable entry in place of a row of glands, IP66

    The short answer

    Decided before the enclosure is ordered

    Panel inches go three places: parts that each do one job, heat that needs clearance and cooling, and wiring that needs room to land. The inches come back from parts that combine jobs, parts that shed less heat, and hardware that sits in the product or at the wall and off the main rail. Settle the layout before the enclosure is ordered.

    What it costs when it goes wrong

    In the builder's terms

    The next enclosure size up

    A panel that will not close goes up a size, and the machine frame, the door swing and the floor plan move with it.

    Heat with nowhere to go

    Pack a panel tight and the heat has to be planned. Figure roughly one to one and a half watts per amp through a solid state relay, and leave the heat sink its room.

    A row of glands on the wall

    Every cable through the wall takes a gland and the spacing around it, and a pre-terminated cable loses its connector on the way in.

    A rework after the layout

    The data port and the entry are part numbers when they are decided early and change orders when they are decided late. A meter added late, with no rail left to sit on, is a change order too.

    The parts that answer it

    Power it. Control it. Prove it.

    One part per decision, each with one fact from its own sheet. The brand name opens that product line.

    Premium PSU DIN-rail power product
    Power it · Premium PSU

    Premium PSU GaN power supplies

    The supply sets how much rail and how much clearance the DC bus takes.

    The printed fact. Custom AC/DC supplies from 50 W to 60 kW. More watts per inch, less heat to dump.

    Premium PSU at DynamicStage 06 on the design path

    Celduc okpac solid state relay
    Power it · Celduc

    Celduc celpac and okpac solid state relays

    Switching in a slim DIN-rail package, with versions that arrive on their own heat sink.

    The printed fact. 22.5 mm DIN-rail celpac and 45 mm okpac packages, single to four phase, with ready-to-use versions with heatsinks.

    Celduc at DynamicStage 07 on the design path

    IMO miniature circuit breakers
    Control it · IMO Automation

    IMO contactors and motor circuit breakers

    The motor branch from one catalog, with a coil that runs cool in a tight panel.

    The printed fact. Contactors from compact through heavy industrial frames with a 3 W sealed coil that runs cool, and UL 489 miniature circuit breakers beside them.

    IMO Automation at DynamicStage 04 on the design path

    GETT InduSmart panel PC
    Control it · GETT

    GETT InduSmart panel PCs

    The display and the computer are one fanless unit in the door.

    The printed fact. Panel PCs from 10.1 to 21.5 inches, IP65 front, fanless, Windows or Linux.

    GETT at DynamicStage 10 on the design path

    Brainboxes board-level Ethernet switch
    Prove it · Brainboxes

    Brainboxes board-level Ethernet switches

    The network switch is designed into the product, so it takes no rail in the panel.

    The printed fact. Board-level switching 55 by 55 by 10 millimeters, rated -40 to +85 C, designed into the enclosure instead of bolted on.

    Brainboxes at DynamicStage 11 on the design path

    SATEC BFM-II branch feeder monitor
    Prove it · SATEC

    SATEC BFM-II and PRO series meters

    One device on the rail where the panel would otherwise carry several.

    The printed fact. BFM-II: up to 54 single-phase or 18 three-phase circuits from one DIN-rail unit. PRO: a Class 0.2S revenue meter and a Class A power quality analyzer in one device.

    SATEC at DynamicStage 03 on the design path

    Conta-Clip KDS split cable entry
    Foundation · Conta-Clip

    Conta-Clip KDS split cable entry

    The enclosure wall stops being a row of glands, and the cables keep their connectors.

    The printed fact. The cable goes through the frame with its connector on and the frame holds IP66. UL Recognized, one frame in place of a row of glands, seals swapped from outside.

    Conta-Clip at DynamicStage 13 on the design path

    Conta-Clip PPVK push-in distribution blocks on a DIN rail
    Foundation · Conta-Clip

    Conta-Clip PPVK push-in distribution blocks

    The splits come off the feed on the rail itself.

    The printed fact. Finger-safe power distribution blocks for the splits from the feed, with screw, spring cage, push-in and stud connections on one rail system.

    Conta-Clip at DynamicStage 05 on the design path

    Read the detail

    • Screw, spring or push-in: choosing a DIN-rail terminal block type
    • Requirements for proper cable gland specification
    • Energy efficient machine design: rethinking power components
    • Advantages of solid state relays over electromechanical relays

    See it worked out

    • Wired to Last: blocks, entries and connectors
    • Power That Performs: the power path through the panel
    • The design path: fourteen stages, one part decision at each

    Semiconductor and testRoboticsCommercial equipment

    Go to the product lines

    Premium PSUCelducIMO AutomationGETTBrainboxesSATECConta-Clip

    Every product line on one page

    Also designing for:

    Cost and total cost of ownership

    Questions engineers ask us

    Straight answers on footprint and panel space
    How do I reduce control panel size without losing I/O?

    Look at the three places the inches go: parts that each do one job, heat that needs clearance, and wiring room. Combine jobs in one device where its sheet supports it. A SATEC PRO, for example, is a Class 0.2S revenue meter and a Class A power quality analyzer in one. Pick parts that shed less heat. Pass pre-terminated cables through one split frame in place of a row of glands.

    Does a solid state relay save panel space?

    It can. Celduc celpac relays are 22.5 mm wide on the DIN rail, and there are ready-to-use versions with heatsinks. The heat still has to go somewhere: figure roughly one to one and a half watts dissipated per amp conducted. If there is no thermal budget left in the panel, an electromechanical contactor may be the better part, and we carry those too.

    How do pre-terminated cables get through the enclosure wall without a row of glands?

    With a split cable entry. The cable goes through the Conta-Clip KDS frame with its connector on, the wave-cut seal closes around it, and the frame holds IP66. It is UL Recognized, and the seals are swapped from outside.

    Can the Ethernet switch go inside the product and off the panel rail?

    Yes. Brainboxes board-level switching is 55 by 55 by 10 millimeters, rated -40 to +85 C, and designed into the enclosure instead of bolted on.

    What do you need from us to look at panel space?

    The enclosure size you are trying to hold, the panel layout, the one-line and the cable schedule. From that an application engineer walks the design path with you and names where the inches come back.

    Challenge us

    After 30-plus years in the industrial hardware space we know these products, on our line card and off it. Bring us your most stringent or most mundane requirement. If one of our product lines fits, we will show you where. If it does not, we know someone who will. We would be happy to help.

    Ask a question Call (408) 780-9190

    Take the line card with you

    Every product line on two pages, in the order a machine gets designed.

    Download the line card (PDF)

    Keep readingDesign guidanceThe Dynamic Detail blogWired to LastThe design pathAll product lines
    • Contact Us
    • About Us
    • Our Story
    • Partner with Us
    ©2026 DMCS® -  All rights reserved. Privacy
    Dynamic Measurement and Control Solutions, LLC