The product lines for the machine on a washed floor and the plant around it: power connection sealed where the water hits, the heat and motion control inside the machine, and the metering that says what a line costs to run. The manufacturers Dynamic Measurement and Control Solutions represents, on a line card built for the way you design, with an application engineer on the phone before the spec locks.

The receptacle and the switch are one unit: the circuit cannot be made or broken under load, and the handle takes a lock. IP67 sealed, so the hose-down does not decide when the line stops. Series II pin and sleeve, 20 to 100 A at 125 to 480 V, UL Listed and CSA Certified together, built in Somerset, New Jersey.

Procon rectangular connectors carry power and control through one hood. Mate the inserts, snap the hood, energize. Washdown versions to IP68, on the panel that gets sprayed every shift, and distribution assemblies with breaker protection built in so the outlets move with the layout instead of the conduit.

Solid state relays for ovens, fryers, sealing bars, reheat and CIP heaters, 4 to 125 A single and three phase, with relays and plug-on modules that report mains, load and protection status. Miniature Faston-terminal relays for the inside of a coffee machine or a vending cabinet. A broken element drops the load current and the relay flags it before a day of product is made wrong.

A 300 W AC/DC supply sealed to IP68, mounted where there is no enclosure to put it in, and the CMS family sealed to IP67 for the DC bus on a mobile unit. From the shop that builds 50 kW rail converters, with -40 to +70 C ranges available across the line.

Jaguar drives, including harsh-environment models built for vibration, contactors and motor control from compact to heavy frames, iSmart smart relays and XGB PLCs with license-free programming, iView HMIs on the door. UL-approved miniature circuit breakers, RCBOs and surge protection for the refrigeration and auxiliary circuits. Up to 5-year warranty on electromechanical components, same-day dispatch from US stock.

A splash-water-protected terminal for the filling area: IP65, stainless housing with a glass pane, a membrane keypad with a trackball, connections routed to floor level so the rating survives foaming agent and the pressure washer. Glass keyboards to IP68 that wipe clean, and an optical switch that is never touched at all.

PM17x PRO on the service records demand the way the tariff bills it and stamps every event to 1 microsecond, so the compressor start that landed on the peak is a line in a log, not an argument. Demand is set in minutes and paid all month; seeing which minutes is the first step to moving them.

BFM-II meters up to 54 single-phase or 18 three-phase circuits from one DIN-rail unit, against two voltage sources. Ovens, chillers, compressed air and each line get their own kWh, so a run has a cost and the off weeks have a number.

Remote I/O picks up states, counts and temperatures at the sensor and presents them as Modbus TCP devices your own software polls; RTD and thermocouple modules put oven and cooler temperatures on the same network. The qualified controller is never touched, so what was validated stays validated.

The machine that only has an RS-232 or RS-485 port goes on the network through it, and the plant PC still sees the same COM port. Nothing in the software changes, which is where these projects usually die. Compact unmanaged and PoE switches on the DIN rail carry the new drops from inside the panel you have.

KES entries in signal blue with an elastomer built to FDA food-contact requirements, a flat visible face with no dirt pockets, up to 32 conductors sealed to IP66. A lower-cost alternative to stainless glands in the washdown zone; KDS split entries for the pre-terminated cables on the rest of the machine.

COMBI junction boxes to IP66, UV and ozone resistant, quarter-turn lids, membrane entries that need no locknut, for the compressor room, the yard and the dock. Glands, venting and the Brace conduit system around them, from a company that started on ships in 1919.
If any part of this page raises a question mid-design, whether that is the connector on the machine, the heat zone or the meter on the line, that question is exactly what we are for. A short technical conversation before the spec locks usually surfaces the options a datasheet does not.
Power it. Control it. Prove it.
The same twelve tiles as a two-page PDF: power connection sealed where the water hits, the heat and motion control inside the machine, and the metering that says what a line costs, with the band each manufacturer sits in. Made for the drawing set, not the inbox.
All product lines, including Schaltbau DC switching and Brainboxes networking: www.dynamicrep.com/products